MIDAS/Civil analysis of a two-antenna steel mount in Amarillo, Texas, for 108 mph wind: maximum stress ratio 0.336 and deflection 0.318 in.

Challenge

A steel structure carrying two 35 lb antennas with 1 ft eccentricity needed design and code checking for a 108 mph basic wind speed (Risk Category II).

Approach

The structure was modelled in MIDAS/Civil with wind pressure to ASCE 7-16 (qz = 22.84 psf). Angle, double-angle and HSS members in ASTM SS304 were checked to AISC 360-16 ASD under three load combinations, together with the bolt connection.

Result

The maximum stress ratio was 0.336, deflection 0.318 in against a 0.6 in limit, and bolt shear capacity 8,836 lb against a 39 lb demand.

Scope of Work

  • Wind load derivation
  • Member design and code check
  • Deflection check
  • Bolt shear check

Deliverables

  • Structural analysis report

Codes & Tools

AISC 360-16ASCE 7-16IBC 2020MIDAS/Civil