Cryogenic Heat Exchanger Mechanical Design at −110°C and 112 bar
PV Elite 2019 design of heat exchanger HE-204 to ASME VIII Div.1: −110°C both sides, 112 bar channel, 19 load cases and TEMA tubesheet checks.
Challenge
Heat exchanger HE-204 had to run at −110°C on both sides with 7 bar on the shell side and 112 bar on the channel side, which calls for impact-tested austenitic stainless steel.
Approach
The exchanger (219.1 mm OD, 12.5 mm wall) was designed in SA-403 304 in PV Elite 2019 to ASME VIII Div.1 (2017 edition), with RT-1 radiography on both sides. Nineteen load cases combined pressure, weight, wind and seismic, alongside flange, nozzle MAWP, MDMT and TEMA tubesheet calculations.
Result
A 60-page vessel design report was produced (analysis date 6 March 2026).
Scope of Work
- Internal and external pressure design
- Flange and nozzle MAWP
- MDMT verification
- TEMA tubesheet calculation
Deliverables
- 60-page PV Elite design report
Codes & Tools
Similar projects

FRP Wet Chlorine Line Material Upgrade and Integrity Assessment
Material selection, FEM thickness design and thermal analysis for upgrading a 100°C wet chlorine FRP line at Engro Polymer & Chemicals.

Low Grade Refining Column Design with 14 Bubble Cap Trays for Alcohol Distillation
EN 13445/ASME design of a 700 mm SS 304L alcohol refining column with 14 bubble cap trays, rated −1 to +3 bar g at 127°C.

Steel Structures for a 65 KLPD Ethanol Fermentation and Distillation Plant
Design and detailed engineering of fermentation and distillation steel structures and civil foundations for a 65 KLPD ENA ethanol plant at Chashma.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.