Cryogenic Heat Exchanger Mechanical Design at −110°C and 112 bar

Cryogenic Heat Exchanger Mechanical Design at −110°C and 112 bar

Project Lead
Syed Nasir
Lead Consultant, Founder & CEO, Fluxiss
Discipline Lead
Mr. Hasan Ayaz
Static Equipment Lead, Fluxiss
Discuss a similar project

PV Elite 2019 design of heat exchanger HE-204 to ASME VIII Div.1: −110°C both sides, 112 bar channel, 19 load cases and TEMA tubesheet checks.

Challenge

Heat exchanger HE-204 had to run at −110°C on both sides with 7 bar on the shell side and 112 bar on the channel side, which calls for impact-tested austenitic stainless steel.

Approach

The exchanger (219.1 mm OD, 12.5 mm wall) was designed in SA-403 304 in PV Elite 2019 to ASME VIII Div.1 (2017 edition), with RT-1 radiography on both sides. Nineteen load cases combined pressure, weight, wind and seismic, alongside flange, nozzle MAWP, MDMT and TEMA tubesheet calculations.

Result

A 60-page vessel design report was produced (analysis date 6 March 2026).

Scope of Work

  • Internal and external pressure design
  • Flange and nozzle MAWP
  • MDMT verification
  • TEMA tubesheet calculation

Deliverables

  • 60-page PV Elite design report

Codes & Tools

ASME BPVC Section VIII Div.1 (2017)TEMAASME B16.5PV Elite 2019
Our Pressure Vessel Design service
Ready to Start Your Project?

Let's Build Something Great Together.