FRP Wet Chlorine Line Material Upgrade and Integrity Assessment

FRP Wet Chlorine Line Material Upgrade and Integrity Assessment

Pakistan

Project Lead
Syed Nasir
Lead Consultant, Founder & CEO, Fluxiss
Discipline Lead
Hasnain
FEA/CFD Lead, Fluxiss
Discuss a similar project

Material selection, FEM thickness design and thermal analysis for upgrading a 100°C wet chlorine FRP line at Engro Polymer & Chemicals.

Challenge

Engro Polymer & Chemicals needed to upgrade its AVGU wet chlorine transfer line from PVC FRP to a higher-performance FRP, for 100°C and −5 kPa to 100 kPa design conditions. Fluxiss carried out this work as engineering subcontractor.

Approach

Fluxiss selected Derakane 470 novolac epoxy vinyl ester resin and checked its resistance to wet chlorine at 100°C. Structural, veil and corrosion barrier layer thicknesses were set by FEM in SolidWorks and ANSYS Workbench 16.2, and thermal expansion and the existing supports were reviewed.

Result

All stresses were within ASME/FRP code allowables, thermal expansion from ambient to 100°C was confirmed safe, expansion joints were confirmed suitable, and support modifications were recommended.

Scope of Work

  • Resin and material selection
  • FEM thickness design
  • Thermal expansion analysis
  • Support system review

Deliverables

  • Integrity assessment report
  • Layer thickness specification
  • Support modification recommendations

Codes & Tools

ASME RTP-1ANSYS Workbench 16.2SolidWorks
Our Pipe Stress Analysis service
Ready to Start Your Project?

Let's Build Something Great Together.