Large-Span Aluminium Trilite Space Frame Analysis for Event Use
STAAD.Pro analysis of a 2,380-node aluminium Trilite space frame under dead and wind loads, forming the basis for safe working load certification.
Challenge
A large-span aluminium Trilite space frame for events and exhibitions needed a high strength-to-weight ratio, rapid deployment and structural certification under dead and wind load combinations.
Approach
The frame was modelled in STAAD.Pro CONNECT Edition with 2,380 nodes and 4,525 elements, 12.7 mm lacing bars, 50.8 mm main chords and 30 pinned base supports. Dead, Wind-X and Wind-Z cases were combined into eight load combinations.
Result
Member forces, displacements and envelopes for all eight combinations were reported as the basis for SWL certification (Job ATA1582, Rev. 0, 3 July 2025).
Scope of Work
- 3D space frame model
- Wind and dead load combinations
- Member force and displacement results
Deliverables
- Full STAAD.Pro model and 1,687 pages of output
- 3D, top, side and front views
- Section property tables and material schedule
- SWL certification basis
Similar projects

Building Services Pipe Stress Analysis for the Everton Stadium Project
White-label subcontract pipe stress analysis for the Everton Stadium project: mechanical, domestic and gas piping across movement joints up to 120 mm.
Pipe Stress Analysis of Plantrooms and 34-Floor Risers in a London Office Tower
Lead pipe stress analysis for The Leadenhall Building, London: plantrooms, floor pipework and risers to 34 floors, with support loads marked on drawings.

Steel Warehouse Structural Design with Fabrication-Ready DXF and 3D Model
Full steel warehouse design with Forge Steel, delivered as a fabrication-ready DXF and GLB 3D model for the steelwork contractor.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.