Aluminium 6061 Trailer Structural FEA for Static, Dynamic, Braking and Turning Loads

Aluminium 6061 Trailer Structural FEA for Static, Dynamic, Braking and Turning Loads

Project Lead
Syed Nasir
Lead Consultant, Founder & CEO, Fluxiss
Discipline Lead
Hasnain
FEA/CFD Lead, Fluxiss
Discuss a similar project

ANSYS FEA of a 7×12 Al 6061 trailer across four load cases: all passed (minimum FOS 1.255), with critical joint and weld recommendations.

Challenge

A 7×12 aluminium 6061 trailer had to be shown safe under base pressure, dynamic, braking and turning loads.

Approach

Four load cases were run in ANSYS 2024 R1: 12 kPa base pressure, 36 kPa dynamic (3× factor), 0.6 g braking and 0.5 g turning, each with self weight.

Result

Minimum factors of safety were 3.625 (LC1), 1.255 (LC2) and at least 15 for braking and turning. The lower forward frame joint was identified as critical, and weld sizing and local reinforcement were recommended.

Scope of Work

  • Static and dynamic load cases
  • Braking and turning inertial cases
  • Critical joint identification

Deliverables

  • Von Mises stress plots
  • Deformation plots
  • Safety factor maps
  • Weld and reinforcement recommendations

Codes & Tools

ANSYS 2024 R1
Our Computer Aided Engineering (CAE) service