Blast Shelter Explicit Dynamics Analysis Under Detonation Loading
ANSYS Explicit Dynamics simulation of a 5 m blast shelter under detonation, identifying failure zones (minimum safety factor 0.339) for redesign.
Challenge
A blast and explosion shelter needed its transient structural response to detonation loading quantified to guide redesign.
Approach
A full-scale model of about 5,000 mm length was solved in ANSYS 2024 R1 Explicit Dynamics over 4,686 cycles.
Result
Maximum stress was 737.98 MPa and maximum deformation 181.56 mm. The minimum safety factor of 0.339 showed failure at critical zones and identified the regions needing design changes.
Scope of Work
- Explicit dynamics modelling
- Stress, deformation and safety factor mapping
Deliverables
- Stress and deformation contours
- Safety factor distribution
- Animated deformation video
Similar projects

FRP Wet Chlorine Line Material Upgrade and Integrity Assessment
Material selection, FEM thickness design and thermal analysis for upgrading a 100°C wet chlorine FRP line at Engro Polymer & Chemicals.

Composite Overwrapped Pressure Vessel FEA Across 12 Load Cases
ANSYS assessment of a carbon fibre COPV to ANSI/AIAA S-081B-2018 for proof, burst, vacuum and thermal cases, defining redesign before flight approval.

Aluminium 6061 Trailer Structural FEA for Static, Dynamic, Braking and Turning Loads
ANSYS FEA of a 7×12 Al 6061 trailer across four load cases: all passed (minimum FOS 1.255), with critical joint and weld recommendations.
Let's Build Something Great Together.