ANSYS assessment of a carbon fibre COPV to ANSI/AIAA S-081B-2018 for proof, burst, vacuum and thermal cases, defining redesign before flight approval.

Challenge

A composite overwrapped pressure vessel (270 mm ID, 810 mm cylinder, Al-Mg-Sc liner) needed a structural assessment for proof, burst, external vacuum, temperature extremes and combined cases before flight certification.

Approach

Fluxiss built a layered ANSYS model with an 8.8 mm liner and 64 composite layers (28 helical at 30°, 36 hoop at 90°). Hashin fiber and matrix failure criteria were evaluated across 12 load cases (STR-1 to STR-12).

Result

The liner exceeded yield at proof pressure (386.73 MPa against 300 MPa) and at burst. The composite failed at proof (Hashin index 14.47), while external vacuum was safe with a buckling multiplier of 38.01. The report set out the redesign needed for liner thickness and composite schedule (Rev. 0, 23 March 2026).