296 kW Elevated Commercial Rooftop Solar PV Design
Pakistan
PVSyst-simulated 296 kW elevated rooftop system with 501 × 590 W modules on chemically anchored steel structure, plus layout and wiring drawings.
Challenge
A commercial client in Pakistan needed a roughly 300 kW system on an RCC roof, raised on an elevated steel structure.
Approach
Fluxiss laid out 501 × 590 W JiNKO modules facing south at a 3° tilt on 9 ft and 14 ft poles with chemical anchoring, specified Chint protection, earthing and cables, and simulated the system in PVSyst with a shading analysis.
Result
Layout, wiring diagram, PVSyst simulation and shading report were delivered.
Scope of Work
- Elevated structure design
- Electrical configuration
- Shading analysis
- Energy simulation
Deliverables
- Layout drawing
- Wiring diagram
- PVSyst simulation
- Shading report
Similar projects

11 kW Rooftop Solar PV Design for a University Engineering Department
HelioScope design of a 10.8 kWdc system for NED University's Mechanical Department: 17.65 MWh a year against a 12.77 MWh load, PR 82.8%.

1.3 GWac Utility-Scale Solar PV Plant Design in Colorado
RatedPower design of Inovateus Solar's 1.33 GWac Kendall Ranch: 151 power stations, 40,678 trackers, 3.41 TWh in year 1 and PR 87.03%.

41.6 GWh Commercial Solar Plant Energy Yield Simulation in PVSyst
PVSyst v7.4.8 simulation for the TCP Godowns solar plant: 41.6 GWh a year to grid, P50 1,724 kWh/kWp and PR 82.29%.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.