1.3 GWac Utility-Scale Solar PV Plant Design in Colorado
Limon, Colorado, USA· 2026
RatedPower design of Inovateus Solar's 1.33 GWac Kendall Ranch: 151 power stations, 40,678 trackers, 3.41 TWh in year 1 and PR 87.03%.
Challenge
Inovateus Solar's Kendall Ranch CO, a greenfield plant near Limon, Colorado, needed a complete design package from site characterisation to SLDs, cable schedules, energy yield and financial projections. Fluxiss carried out this work as engineering subcontractor.
Approach
Fluxiss mapped 7,088 acres of suitable land and placed single-axis trackers at 23 ft pitch and 34% GCR. It designed 151 power stations (two SMA 4400 UP inverters and an 8.8 MVA transformer each) and a 20 kV MV collector network, using SRTM-30 terrain and NREL weather data.
Result
Design Revision 09 (11 May 2026) gives 1.329 GWac / 1.595 GWdc, 3.41 TWh year-1 energy at 87.03% PR, and a 25-year NPV of $2.83 billion at a 6% discount rate.
Scope of Work
- Site and topography analysis
- Tracker layout
- Power station and MV network design
- Energy yield and 25-year financial model
Deliverables
- Design report (151 sheets)
- Energy yield report
- Layouts and SLDs (MV, LV, string boxes)
- Cable and post listings
- WECC power flow model
- Financial analysis
Codes & Tools
Similar projects

11 kW Rooftop Solar PV Design for a University Engineering Department
HelioScope design of a 10.8 kWdc system for NED University's Mechanical Department: 17.65 MWh a year against a 12.77 MWh load, PR 82.8%.

41.6 GWh Commercial Solar Plant Energy Yield Simulation in PVSyst
PVSyst v7.4.8 simulation for the TCP Godowns solar plant: 41.6 GWh a year to grid, P50 1,724 kWh/kWp and PR 82.29%.

296 kW Elevated Commercial Rooftop Solar PV Design
PVSyst-simulated 296 kW elevated rooftop system with 501 × 590 W modules on chemically anchored steel structure, plus layout and wiring drawings.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.