Pipe Stress Analysis projects.

Pipe stress analysis checks sustained, expansion, operating and hydrotest stresses against code allowables and sets the support strategy. Fluxiss uses CAESAR II and AutoPIPE to ASME B31.3/B31.4/B31.8 and BS EN 13480-3, including API-610/617 nozzle checks.

7 projects

Fluxiss Pipe Stress Analysis work.

Every project below was led by Syed Nasir, Lead Consultant and Founder & CEO.

Cryogenic LNG Pipeline Stress Analysis and Support Redesign at −162°C
Oil & Gas · Pipe Stress Analysis

Cryogenic LNG Pipeline Stress Analysis and Support Redesign at −162°C

CAESAR II stress analysis of a 2-inch stainless LNG line at −162°C feeding flow meters and a cryogenic pump, rerouted and re-supported to pass ASME B31.3.

View project
6-Inch Natural Gas Line Stress Analysis from Measuring Station to Gas Dryer
Oil & Gas · Pipe Stress Analysis

6-Inch Natural Gas Line Stress Analysis from Measuring Station to Gas Dryer

Existing-versus-modified CAESAR II analysis of a 6-inch carbon steel gas line with buried branches, bringing all stresses within ASME B31.3 allowables.

View project
Pipe Stress Analysis for a Large Water Treatment Plant with Pipe Sizes to DN1600
Power & Utilities · Pipe Stress Analysis

Pipe Stress Analysis for a Large Water Treatment Plant with Pipe Sizes to DN1600

AutoPIPE stress analysis to BS EN 13480 across all piping systems at Thames Water's Becton plant, with pipe sizes up to DN1600.

Becton, London, UKView project
Chilled Water Pipe Stress Analysis up to DN1000 for Microsoft MS-LON1
Data Centres & Telecom · Pipe Stress Analysis

Chilled Water Pipe Stress Analysis up to DN1000 for Microsoft MS-LON1

Lead pipe stress analysis, as subcontractor, of CHW piping up to DN1000 for Microsoft MS-LON1, with a friction factor study for product selection.

GermanyView project
Building Services Pipe Stress Analysis for the Everton Stadium Project
Buildings & Venues · Pipe Stress Analysis

Building Services Pipe Stress Analysis for the Everton Stadium Project

White-label subcontract pipe stress analysis for the Everton Stadium project: mechanical, domestic and gas piping across movement joints up to 120 mm.

Liverpool, UKView project
Pipe Stress Analysis of Plantrooms and 34-Floor Risers in a London Office Tower
Buildings & Venues · Pipe Stress Analysis

Pipe Stress Analysis of Plantrooms and 34-Floor Risers in a London Office Tower

Lead pipe stress analysis for The Leadenhall Building, London: plantrooms, floor pipework and risers to 34 floors, with support loads marked on drawings.

London, UKView project
Hospital Pipe Stress and Acoustic Analysis for Plantrooms and Floor Pipework
Healthcare & Education · Pipe Stress Analysis

Hospital Pipe Stress and Acoustic Analysis for Plantrooms and Floor Pipework

Stress and acoustic analysis of mechanical and domestic piping at Midland Metropolitan University Hospital to reduce noise in a hospital setting.

England, UKView project