Existing-versus-modified CAESAR II analysis of a 6-inch carbon steel gas line with buried branches, bringing all stresses within ASME B31.3 allowables.

Challenge

A 6-inch carbon steel natural gas line from a measuring station to a gas dryer, with several branches including one running into concrete ground, was supported only by guide restraints at three locations.

Approach

The existing and modified systems were both modelled in CAESAR II to ASME B31.3 under sustained, operating, thermal expansion, hydrotest, wind and seismic cases. Overstress areas in the existing configuration formed the basis of the modification design, using additional supports and rerouting.

Result

All stress ratios in the modified system were within ASME B31.3 allowables, and forces and moments at all anchor and support nodes were tabulated for both cases (Rev. 0, 3 June 2025).

Scope of Work

  • Existing condition baseline analysis
  • Overstress identification
  • Support and routing modification design
  • Wind and seismic load cases

Deliverables

  • Stress, displacement and support reaction results
  • Force and moment tables at all supports
  • CAESAR model, input listing and code compliance annexures

Codes & Tools

ASME B31.3CAESAR II