API-650 Design of a 60 ft Hot Asphalt Storage Tank (3,362 m³)

API-650 Design of a 60 ft Hot Asphalt Storage Tank (3,362 m³)

Korangi, Karachi, Pakistan

Project Lead
Syed Nasir
Lead Consultant, Founder & CEO, Fluxiss
Discipline Lead
Mr. Hasan Ayaz
Static Equipment Lead, Fluxiss
Discuss a similar project

Full API-650 calculations for an 18.3 m diameter asphalt tank at 150°C design temperature, SG 1.06, 100 mph wind and seismic zone 2B.

Challenge

Asphalt storage tank S-551 at National Refinery Ltd. stores a heavy product (SG 1.06) at up to 130°C operating and 150°C design temperature, with combined wind and seismic demands on a 60 ft diameter, 42 ft high shell. Fluxiss carried out this work as engineering subcontractor.

Approach

Fluxiss designed the shell by the variable design point method and sized the wind girders, annular and bottom plates, supported cone roof, rafters and columns. Wind overturning, impulsive and convective seismic mass, shell compression, anchorage to API-650 Appendix E and normal and emergency venting were checked.

Result

A full calculation package was delivered for the 3,362 m³ (21,149 BBL) tank with 3 mm corrosion allowance on all plates.

Scope of Work

  • Variable design point shell design
  • Roof, rafter and column design
  • Wind and seismic stability
  • Venting

Deliverables

  • Full tank design calculation report

Codes & Tools

API-650API-650 Appendix EAMETanks
Our Pressure Vessel Design service
Ready to Start Your Project?

Let's Build Something Great Together.

Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.