API-650 Design of a 60 ft Hot Asphalt Storage Tank (3,362 m³)
Korangi, Karachi, Pakistan
Full API-650 calculations for an 18.3 m diameter asphalt tank at 150°C design temperature, SG 1.06, 100 mph wind and seismic zone 2B.
Challenge
Asphalt storage tank S-551 at National Refinery Ltd. stores a heavy product (SG 1.06) at up to 130°C operating and 150°C design temperature, with combined wind and seismic demands on a 60 ft diameter, 42 ft high shell. Fluxiss carried out this work as engineering subcontractor.
Approach
Fluxiss designed the shell by the variable design point method and sized the wind girders, annular and bottom plates, supported cone roof, rafters and columns. Wind overturning, impulsive and convective seismic mass, shell compression, anchorage to API-650 Appendix E and normal and emergency venting were checked.
Result
A full calculation package was delivered for the 3,362 m³ (21,149 BBL) tank with 3 mm corrosion allowance on all plates.
Scope of Work
- Variable design point shell design
- Roof, rafter and column design
- Wind and seismic stability
- Venting
Deliverables
- Full tank design calculation report
Similar projects

Cryogenic LNG Pipeline Stress Analysis and Support Redesign at −162°C
CAESAR II stress analysis of a 2-inch stainless LNG line at −162°C feeding flow meters and a cryogenic pump, rerouted and re-supported to pass ASME B31.3.

6-Inch Natural Gas Line Stress Analysis from Measuring Station to Gas Dryer
Existing-versus-modified CAESAR II analysis of a 6-inch carbon steel gas line with buried branches, bringing all stresses within ASME B31.3 allowables.

Seismic Pipe Stress and API-617 Compressor Nozzle Assessment for a Refinery Upgrading Project
Seismic and static analysis of a 6-inch refinery line where one added support brought compressor nozzle loads from fail to pass under API-617.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.