Six-Tank API-650 Design Calculation Package for a Refinery at Korangi, Karachi

Six-Tank API-650 Design Calculation Package for a Refinery at Korangi, Karachi

Korangi, Karachi, Pakistan

Project Lead
Syed Nasir
Lead Consultant, Founder & CEO, Fluxiss
Discipline Lead
Mr. Hasan Ayaz
Static Equipment Lead, Fluxiss
Discuss a similar project

API-650 design of six utility and process tanks (45.6 to 1,160 m³) for National Refinery and OGDCL, for wind up to 160 mph and seismic zones 2A/2B.

Challenge

National Refinery Ltd. and OGDCL needed design calculations for six tanks storing raw water, fire water, produced water, potable water, diesel and condensate, ranging from 45.6 m³ to 1,160 m³. Fluxiss carried out this work as engineering subcontractor.

Approach

All six column-rafter supported cone roof tanks were designed to API-650 Tenth Edition, covering shell thickness (1-foot method), wind girders, annular, bottom and roof plates, wind and seismic stability, anchorage, venting, rafters and columns.

Result

A complete six-tank calculation package was issued, with each tank checked for wind speeds up to 160 mph and seismic zone 2A or 2B.

Scope of Work

  • Shell, bottom and roof design
  • Wind overturning and sliding
  • Seismic effective mass and anchorage
  • Venting and rafter/column design

Deliverables

  • Six tank design calculation reports (Job Order 078-9)

Codes & Tools

API-650 (Tenth Edition)AMETanks