Six-Tank API-650 Design Calculation Package for a Refinery at Korangi, Karachi
Korangi, Karachi, Pakistan
API-650 design of six utility and process tanks (45.6 to 1,160 m³) for National Refinery and OGDCL, for wind up to 160 mph and seismic zones 2A/2B.
Challenge
National Refinery Ltd. and OGDCL needed design calculations for six tanks storing raw water, fire water, produced water, potable water, diesel and condensate, ranging from 45.6 m³ to 1,160 m³. Fluxiss carried out this work as engineering subcontractor.
Approach
All six column-rafter supported cone roof tanks were designed to API-650 Tenth Edition, covering shell thickness (1-foot method), wind girders, annular, bottom and roof plates, wind and seismic stability, anchorage, venting, rafters and columns.
Result
A complete six-tank calculation package was issued, with each tank checked for wind speeds up to 160 mph and seismic zone 2A or 2B.
Scope of Work
- Shell, bottom and roof design
- Wind overturning and sliding
- Seismic effective mass and anchorage
- Venting and rafter/column design
Deliverables
- Six tank design calculation reports (Job Order 078-9)
Similar projects

Cryogenic LNG Pipeline Stress Analysis and Support Redesign at −162°C
CAESAR II stress analysis of a 2-inch stainless LNG line at −162°C feeding flow meters and a cryogenic pump, rerouted and re-supported to pass ASME B31.3.

6-Inch Natural Gas Line Stress Analysis from Measuring Station to Gas Dryer
Existing-versus-modified CAESAR II analysis of a 6-inch carbon steel gas line with buried branches, bringing all stresses within ASME B31.3 allowables.

Seismic Pipe Stress and API-617 Compressor Nozzle Assessment for a Refinery Upgrading Project
Seismic and static analysis of a 6-inch refinery line where one added support brought compressor nozzle loads from fail to pass under API-617.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.