Buried and Above-Ground Oil Pipeline Stress and Surge Analysis from Tanker Berth to Terminal
India· 2024
Static and surge analysis of a 406 mm buried and above-ground oil pipeline from a tanker berth to a terminal, with all cases passing BS EN 13480-3.
Challenge
A 406 mm OD carbon steel oil pipeline from the South Oil Tanker Berth to the HPCL Terminal needed static stress analysis to BS EN 13480-3 and dynamic surge analysis for a 2.5-second valve closure. Buried and above-ground sections at different elevations required two modelling approaches.
Approach
Working as subcontractor, Fluxiss modelled both sections in CAESAR II using guides, rigid hangers, anchors and skid supports. Sustained, expansion and hydrotest cases were run to BS EN 13480-3, and surge analysis used a fluid density of 1,000 kg/m³ and 2.5 s valve closure. Expansion strategies were developed separately for buried and above-ground sections.
Result
All sustained, expansion and hydrotest stresses passed BS EN 13480-3, surge pressure transients were quantified, and loads at anchors and key supports were tabulated. Issue 02 of the report (26 November 2024) added the surge analysis, with a DXF of support locations supplied to the contractor.
Scope of Work
- Buried pipeline soil-pipe interaction strategy
- Above-ground guide, anchor and hanger strategy
- Valve-closure surge analysis
- Support load tabulation
Deliverables
- Stress analysis report Issue 02
- Design information and RFI log Rev. 04
- DXF support location file for construction
- Surge analysis section and boundary condition summary
Similar projects

Cryogenic LNG Pipeline Stress Analysis and Support Redesign at −162°C
CAESAR II stress analysis of a 2-inch stainless LNG line at −162°C feeding flow meters and a cryogenic pump, rerouted and re-supported to pass ASME B31.3.

6-Inch Natural Gas Line Stress Analysis from Measuring Station to Gas Dryer
Existing-versus-modified CAESAR II analysis of a 6-inch carbon steel gas line with buried branches, bringing all stresses within ASME B31.3 allowables.

Seismic Pipe Stress and API-617 Compressor Nozzle Assessment for a Refinery Upgrading Project
Seismic and static analysis of a 6-inch refinery line where one added support brought compressor nozzle loads from fail to pass under API-617.
Let's Build Something Great Together.
Partner with Fluxiss for engineering that holds up - under pressure, under load, under scrutiny.